Please enter the words you want to search for:

[Return to folder listing]

   Switching Losses in a 1.7 kW GaN based Full-Bridge DC-DC Converter with Synchronous Rectification   [View] 
 [Download] 
 Author(s)   RAKESH RAMACHANDRAN 
 Abstract   The paper presents the detailed analysis of switching losses in GaN devices for an isolated full-bridge dc-dc converter. Switching losses includes capacitive losses along with turn-on and turn-off losses of the power MOSFET. In hard switched converters, the output capacitance of MOSFET contributes to a significant part of the switching loss. The capacitive loss analysis also helps in determining the optimum number of devices used in parallel for a given power level and switching frequency. The analysis is performed on a 1.7 kW full bridge isolated dc-dc GaN converter at a switching frequency of 50 kHz. The paper also presents the GaN switch efficiency curve for an isolated dc-dc GaN converter with different number of devices in parallel. 
 Download 
Filename:0781-epe2015-full-11231318.pdf
Filesize:492.5 KB
 Type   Members Only 
 Date   Last modified 2016-06-08 by System