Influence of Modulation Method on Using LC-Traps with Single-Phase Voltage Source Inverters
| [View]
[Download]
|
Author(s) |
Xiongfei WANG |
Abstract |
The switching-frequency LC-trap filter has recently been employed with high-order passive filters for Voltage Source Inverters (VSIs). This paper investigates the influence of modulation method on using the LC-traps with single-phase VSIs. Two-level (bipolar) and three-level (unipolar) modulations that include phase distortion and alternative phase opposition distortion methods are analyzed. Harmonic filtering performances of four LC-trap-based filters with different locations of LC-traps are compared. It is shown that the use of parallel-LC-traps in series with filter inductors, either grid or converter side, has a worse harmonic filtering performance than using series-LC-trap in the shunt branch. Simulations and experimental results are presented for verifications. |
Download |
Filename: | 0821-epe2015-full-13491189.pdf |
Filesize: | 2.261 MB |
|
Type |
Members Only |
Date |
Last modified 2016-06-08 by System |
|
|