   IMPACT OF SEMI-MAGNETIC SLOT KEY ON THE PERFORMANCE OF A TOOTH-COIL TRACTION MOTOR   [View] 
 [Download] 
 Author(s)   Juho MONTONEN 
 Abstract   Fractional-slot non-overlapping-winding permanent magnet synchronous machine for traction application is designed. Detailed comparison of the performance of electrical machine is provided with and without semi-magnetic slot wedges. Usage of slot wedges brings some efficiency benefits while partially eliminating permanent magnet losses. It however, increases the synchronous inductance which results in lower peak torque but a higher field weakening area. 
 Download 
Filename:0578-epe2015-full-08592727.pdf
Filesize:238 KB
 Type   Members Only 