IDENTIFICATION AND COMPENSATION OF THE DEAD TIME BEHAVIOUR OF AN INVERTER
| [View]
[Download]
|
Author(s) |
Th. Baumann |
Abstract |
The knowledge of the output voltage of an inverter is required to obtain a high
robustness of the (encoderless) field oriented control of an induction machine. The paper presents one method of self parametrisation of an inverter-fed induction machine drive. This
approach identifies the parameters for dead time compensation and the stator resistance of the induction machine at stand-still. This method is implemented in inverters for different power ranges as one part of the parameter identification at stand still. |
Download |
Filename: | Unnamed file |
Filesize: | 265.5 KB |
|
Type |
Members Only |
Date |
Last modified 2016-03-09 by System |
|
|