Please enter the words you want to search for:

[Return to folder listing]

   IMPROVEMENT OF THE POWER FACTOR OF DIMMERS USING HIGH FREQUENCY ZERO CURRENT SWITCHING   [View] 
 [Download] 
 Author(s)   K.-J. Lux; G. Schröder; H. Siebel; B. H. Yu 
 Abstract   With new EMI standards new converter structures and control methods are necessary. In the past usually phase control was the appropriate method for the control of simple ac loads (e.g. lamps). The disadvantage of phase control is generation of additional reactive power and of harmonics in the mains. The circuit proposed in this paper is able to reduce the harmonics in the mains significantly. Reactive power due to control is avoided. A enhanced version additionally avoids significant harmonics at the load side. 
 Download 
Filename:Unnamed file
Filesize:330.9 KB
 Type   Members Only 
 Date   Last modified 2016-03-08 by System