Stiff differential equations of mathematical models of semiconductor systems are solved using SESL2 and FORTRAN languages. The electromechanical rolling mill
system with 2H-type converter is considered as characteristic semiconductor system. The influences of pulses missing in thyristor control, shorting of thyristor, loss of thyristor
blocking ability on characteristic quantities of electromechanical rolling mill system, are determined. The calculation results are presented in a form of diagrams of electromechanical
system responses. A comparison of calculation and measurement results is