Analysis and Diagnosis on Open-circuit Fault of Diode Rectifier in 12-phase Synchronous Generator System
| [View]
[Download]
|
Author(s) |
Ziguo HUANG, Yuguang SUN, Shanming WANG, Xiwen YU |
Abstract |
This paper deals with a 12-phase synchronous generator with open-circuit fault of diode rectifier. Considering all space harmonics of air-gap magnetic field and the changing circuit topology, the mathematical model of the system is established based on the multiloop theory of machine. A series of experiments have been conducted on a 4-kW 12-phase synchronous model machine. The acceptable agreement between the simulated and experimental result validates the modeling process. Based on the analysis, the features of the open-circuit fault of rectifier are summarized. Finally, the algorithm of DC voltage odd harmonic detection is raised. |
Download |
Filename: | 0277-epe2014-full-15585840.pdf |
Filesize: | 313.8 KB |
|
Type |
Members Only |
Date |
Last modified 2015-06-08 by System |
|
|