 Author(s)   Rafal JASTRZEBSKI, Alexander SMIRNOV, Janne NERG, Ahti JAATINEN-VARRI, Pekko JAATINEN, Tuomo LINDH, Olli PYRHONEN, Jussi SOPANEN, Jari BACKMAN 
 Abstract   A commissioning and laboratory tests of an active magnetic bearing supported PM 3kW blower arepresented. The motor operation is evaluated in no-load and load tests. An identification of AMB-rotorsystem, testing of H∞ centralized control and mass-flow of the blower for recirculation of anode gas ina SOFC are discussed. The key results include comparison between analytical and measured values ofan output sensitivity function of different MIMO controllers, measured efficiency and output motorpower, and blower measurements. 