Please enter the words you want to search for:

[Return to folder listing]

   High frequency parameters of a double-fed machineand additional energy losses from a frequency converter   [View] 
 [Download] 
 Author(s)   Grigorii GOGOLEV, Mikhail PRONIN, Alexei VORONTSOV, Andrey VATAYEV, Yirii KOSKIN, Vladislav TRETIAKOV, Vasiliy SHELYUKH 
 Abstract   A prototype of the hydroelectric pumped storage power plant with 2.4 MW asynchronized generatormotorand frequency converter has been produced. The computer models of the system have beendeveloped. The experimental study of high-frequency parameters of the generator-motor windingshave been carried out. The assessment method of the machine additional energy losses caused byconverter voltage distortions have been developed. The power loss comparison in the generator-motorcaused by two-level, three-level and cascaded frequency converters has been done. 
 Download 
Filename:0112-epe2013-full-11003062.pdf
Filesize:1.685 MB
 Type   Members Only 
 Date   Last modified 2014-02-09 by System