Experimental validation of a hybrid emergency network with low and medium voltage Li-Ion batteries for more electrical aircraft
| [View]
[Download]
|
Author(s) |
Fabien LACRESSONNIERE, Eric BRU, Guillaume FONTES, Xavier ROBOAM |
Abstract |
This paper deals with a hybrid electrical network for an aircraft in emergency operation. The principle of this network is to hybridize, through a bidirectional DC/DC converter, a high speed Ram Air Turbine (RAT) with an electrochemical Lithium Ion accumulator. A design study of DC/DC power converters, according to the voltage of the accumulator, is presented. The results of this study have shown that utilization of a medium-voltage battery can be a good mass / efficiency trade off of the overall system. Some experiments on a lab test bench have allowed validating the principle of the hybridization and several energy management strategies have been tested with low and medium voltage lithium ion batteries. |
Download |
Filename: | 0799-epe2013-full-23464371.pdf |
Filesize: | 793.4 KB |
|
Type |
Members Only |
Date |
Last modified 2014-02-09 by System |
|
|