Please enter the words you want to search for:

[Return to folder listing]

   Upgrade of the NSRRC Booster Power Supply   [View] 
 [Download] 
 Author(s)   Chen-Yao Liu; Kuo-Bin Liu; Yao-Ching Hsieh; Alexander Elkiær; Din-Goa Huang 
 Abstract   For the 1.5GeV energy injector upgrade project for the NSRRC synchrotron light source, new ramping power supplies were implemented in the “White circuit” booster synchrotron ring. IGBT semiconductors operating at a higher frequency was employed to replace the older GTO-based system. The new system enabled reduction of the current waveform harmonic distortions and thus improving the injection and extraction efficiency. The increased reliability increased blind power from circuit mistuning also ensures higher system uptimes. The measured dynamic range of the 10 Hz sine wave current output of the new ramping power supply is shown to be better than 75 dB with a total harmonic distortion (THD) less than 0.015 %. From the monitored beam current, the low THD dipole magnets current can greatly improve the stability of the booster beam current. 
 Download 
Filename:Unnamed file
Filesize:484 KB
 Type   Members Only 
 Date   Last modified 2013-07-24 by System