   Turn-off Behavior of 4.5 kV Asymmetric IGCTs under Zero Voltage Switching Conditions   [View] 
 [Download] 
 Author(s)   Robert LENKE, Rik W. DE DONCKER, Jon SAN-SEBASTIAN, Ion ETXEBERRIA-OTADUI, Silvano TARABORRELLI, Hauke VAN HOEK 
 Abstract   This paper presents the experimental characterization of four different types of 4.5 kV, 91 mm asymmetric IGCTs under zero-voltage switching. On-state and turn-off tests at ratings up to 2.8 kV/3.3 kA with several resonant snubber capacitances and different junction temperatures have been performed to obtain experimental data. For converter loss modeling, e.g. dc-to-dc converters for off-shore windfarms, the measured device losses have been used to derive a parameter-dependent fitting function. 
 Download 
Filename:0373-epe2011-full-09231575.pdf
Filesize:1.91 MB
 Type   Members Only 
 Date   Last modified 2012-01-26 by System