   Position Estimation in a True Asymmetric Cascade H-Bridge Multilevel Inverter   [View] 
 [Download] 
 Author(s)   Kamel SALEH, Mark SUMNER 
 Abstract   This paper introduces a new method to track the saliency of motor fed by a multilevel inverter throughmeasuring the dynamic current response of the motor line currents due the IGBT switching actions.The method uses only the fundamental PWM waveform (i.e there is no modification to the operationof the multilevel inverter) similar to the fundamental PWM method proposed for a 2-level inverter.Simulation results are provided to demonstrate the performance of the complete sensorless speedcontrol of a PM motor driven by such a converter over a wide speed range. Finally the paperintroduces a comparison between the 2-level inverter and the multilevel inverter in terms of thereduction of the Total Harmonic Distortion (THD) using the fundamental PWM method in both cases. 
 Download 
Filename:0523-epe2011-full-14294671.pdf
Filesize:902 KB
 Type   Members Only 
 Date   Last modified 2012-01-26 by System