Please enter the words you want to search for:

[Return to folder listing]

   Current Distribution in High Power Laminated Busbars   [View] 
 [Download] 
 Author(s)   Angus BRYANT, Kiran Kumar VADLAPATI, Jonathan STARKEY, Andy GOLDNEY, Stefanos KANDILIDIS, David HINCHLEY 
 Abstract   The new LV8900 900 V variable speed drive range from Converteam utilises 3-level NPC invertertopology, featuring multi-layer laminated busbars. These laminates contribute to the commutating stray inductances, and laminate resistive losses in high current and high switching frequency applications are affected by the skin effect. This paper describes models implemented in FastHenryand Simulink accounting for these effects in the laminates as part of the design process. The results show close matching to experimentally measured laminate losses and correct prediction of stray inductance behaviour. 
 Download 
Filename:0428-epe2011-full-12582430.pdf
Filesize:247.4 KB
 Type   Members Only 
 Date   Last modified 2012-01-26 by System