Please enter the words you want to search for:

[Return to folder listing]

   Control of a doubly-fed induction generator under unbalanced conditions considering the converter limits   [View] 
 [Download] 
 Author(s)   Oriol GOMIS-BELLMUNT, Adrià JUNYENT-FERRE, Andreas SUMPER, Montserrat MATA-DUMENJO, Marc SALA LLUMA 
 Abstract   The present paper addresses the control of doubly fed induction generators under unbalanced voltage sags considering the converter limits. A control strategy is proposed by choosing certain current reference values in the positive and negative sequences so that the torque and the DC voltage are kept stable during such unbalanced sags considering the converter limits. 
 Download 
Filename:0307-epe2009-full-10504650.pdf
Filesize:1.145 MB
 Type   Members Only 